XLXL 테크놀로지
모든 인사이트

설치16 2026월6 분 읽기

기존 유리 파사드에 디스플레이 추가

리트로핏 프로젝트는 유리, 고정 방식, 서비스 경로를 기준으로 결정됩니다. 픽셀 피치를 논의하기 전에 이 요소들을 먼저 확인하세요.

기존 유리 외벽에 디스플레이 추가

Survey the glass before the screen

Existing glazing varies more than new-build facades. Record the glass type, thickness, mullion spacing, seal condition and any opening vents. These details decide whether a film can be bonded or a frame can be fixed.

If the glass is laminated, coated or curved, the fixing method needs to be confirmed with the glass supplier before design proceeds.

Load and fixing

A film adds very little load, but a transparent panel or mesh screen introduces brackets, cabinets and service loads. These must be resolved with the facade engineer rather than assumed.

For listed or sensitive buildings, the fixing strategy may need to avoid drilling the original frame. Clamped or suspended solutions are often possible but require early coordination.

Power, signal and service

Retrofit routes are usually the hardest part. Power and signal need a path from the plant room to the screen without crossing occupied space or breaking the facade line.

Decide who services the screen and how. A front-service panel can avoid internal access, while a rear-service design may require a maintained walkway.

Commissioning and handover

Commission the screen at the brightness and colour settings it will actually run at, not at maximum. Record the settings and the content schedule for the facilities team.

Handover should include spare modules, the control layout and a simple fault guide. Retrofit sites rarely have a dedicated AV team on site.

가이드라인을 명세서로 변환하세요

사이트 정보를 보내주시면 프로젝트의 형식, 피치 및 설치 방식을 확인해 드리겠습니다.

jasmin@xlled.cn

월요일부터 금요일까지, 09:00 ~ 18:00 (GMT+8)

견적 요청